EXHIBIT C
LOCAL AMENDMENTS
PART I
BUILDING REGULATIONS
The Uniform Building Code (UBC) is amended with the following additions, deletions and modifications, made due to topo-geographical, geographical and climatic conditions to the following Sections:
(A) Section 106.4.4 is amended as follows:
Every permit issued by the Building Official under the provisions of this code shall expire and become null and void 180 days from the date of issuance. Any permittee holding an unexpired permit may apply for an extension of a current permit for up to two 180 day extension periods. The maximum allowable total permit time period shall not exceed one and one half (1 1/2) years. The fee for extension of a non-expired permit shall be based upon the portion of the incomplete work. Before any work can be recommenced on an expired permit, a new permit shall be obtained. The cost of a new permit to complete a partially completed structure shall be the estimated cost of the incomplete work based on the valuation per Exhibit B., plus a one hundred dollar administration fee. On permits expired for one year or more, the Codes in effect at the time a new permit is issued shall be the Codes which apply to that permit through the point of completion or expiration, whichever occurs first.
(B) Section 107.3 is amended to read as follows:
When submittal documents are required by Section 106.3.2, a plan review fee shall be paid. Said plan review fee shall be 50% of the building permit fee.
(C) Section 108.3 is amended with the following incorporated into said section to read as follows:
The inspections days and times for the City of Alturas are as follows:
Monday through Friday: 8:00 AM to 12:00 PM
Note: Inspections for days or times other than specified above may be arranged upon approval by the Building Official. Such alternate times may require the charging of fees for overtime for the inspector.
It shall be the duty of the person requesting any inspection required by this code to provide access to and means for inspection of such work.
(D) Section 1504.1 is amended with the following incorporated into said section to read as follows:
(1) Minimum Class C Roof Covering on all new roofs and reroofing for all structures.
(2) All roofs shall have a hot or cold underlayment roofing from the eave overhang for a distance 6 feet above the exterior wall or to the ridge whichever is less, above 6000 feet elevation.
(E) When notified as located in a "State Responsibly Area (SRA), as required by Fire Safe Regulations" the following shall apply:
(1) Minimum Class A Roof Covering shall be required for all structures and re-roofing of existing structures.
(2) Minimum Class B for Shake or shingle siding (rated roofing materials)
(F) Section 1608 is amended with the following incorporated into said section to read as follows:
MINIMUM ROOF SNOW LOADS (lbs. / sq. ft.)
30 lbs.
(G) Section 1806 is amended with the following incorporated into said section to read as follows:
FROST DEPTH REQUIREMENTS
18 in.